Plumbing

1. Acceptable Service Line: Galvanized - Galvanized pipe present
2. Acceptable Main Water Shutoff: Basement
3. Acceptable Water Lines: Copper/Galvinized/PVC
4. Acceptable Drain Pipes: Cast iron
5. Acceptable Service Caps: Accessible
6. Acceptable Vent Pipes: Cast iron
7. Acceptable Gas Service Lines: Black Iron
Basement Water Heater
8. Not Inspected Water Heater Operation: Inadequate - Improper flue routing and connection Recommend repair. Water heater was not installed properly on untreated wood platform Recommend repair.
9. Manufacturer: Craftmaster
10. Model Number: G1F4033S3NV Serial Number: 0307116120
11. Type: Natural gas Capacity: 40 Gal.
12. Approximate Age: 1-5 years Area Served: Whole House
13. Defective Flue Pipe: Metal - Loose pipe connections will allow carbon monoxide into house. This is a safety hazard. Recommend repair.
14. Defective TPRV and Drain Tube: Copper - Relief valve reduced diameter from TPRV. Recommend replacement with full diameter copper tubing.