| 1. |
Acceptable |
Service Line: Galvanized
- Galvanized pipe present |
| 2. |
Acceptable |
Main Water Shutoff: Basement |
| 3. |
Acceptable |
Water Lines: Copper/Galvinized/PVC |
| 4. |
Acceptable |
Drain Pipes: Cast iron |
| 5. |
Acceptable |
Service Caps: Accessible |
| 6. |
Acceptable |
Vent Pipes: Cast iron |
| 7. |
Acceptable |
Gas Service Lines: Black
Iron |
| |
Basement Water Heater
|
| 8. |
Not Inspected |
Water Heater Operation: Inadequate
- Improper flue routing
and connection Recommend repair. Water heater was not installed properly
on untreated wood platform Recommend repair. |
| 9. |
|
Manufacturer: Craftmaster |
| 10. |
|
Model Number: G1F4033S3NV Serial
Number: 0307116120 |
| 11. |
|
Type: Natural gas Capacity: 40
Gal. |
| 12. |
|
Approximate Age: 1-5 years Area
Served: Whole House |
| 13. |
Defective |
Flue Pipe: Metal - Loose
pipe connections will allow carbon monoxide into house. This is a safety
hazard. Recommend repair. |
| 14. |
Defective |
TPRV and Drain Tube: Copper
- Relief valve reduced
diameter from TPRV. Recommend replacement with full diameter copper tubing. |