Basement Heating System
|
| 1. |
Marginal |
Heating System Operation: Not
tested - Not tested. Gas
not turned on at time of inspection. Ameren Gas company representative
arrived during inspection to turn on gas and was unable to light pilot
on furnace. Recommend HVAC service person examine units and repair as
needed, Furnace nearing the end of it's design life |
| 2. |
|
Manufacturer: Williamson |
| 3. |
|
Model Number: T114-45-1 Serial
Number: A8202993 |
| 4. |
|
Type: Forced air. Capacity: N/A |
| 5. |
|
Area Served: Whole House Approximate
Age: 20 -30 years |
| 6. |
|
Fuel Type: Natural gas |
| 7. |
Acceptable |
Heat Exchanger: 1 Burner |
| 8. |
|
Unable to Inspect: N/A |
| 9. |
Acceptable |
Blower Fan/Filter: Belt
drive with disposable filter |
| 10. |
Marginal |
Distribution: Metal duct
and flex - Inadequate air
flow due to crushed duct entering crawlspace. Recommend repair. |
| 11. |
Acceptable |
Draft Control: Automatic |
| 12. |
Marginal |
Flue Pipe: Metal - Flue
partially blocked by bird nest. Recommend removal and installing rain
cap and screen to prevent nesting of birds. |
| 13. |
Acceptable |
Controls: Disconnect;
normal operating and safety controls observed. |
| 14. |
Not Inspected |
Humidifier: Not Inspected
- Not tested |
| |
2nd floor utility closet Heating System
|
| 15. |
Marginal |
Heating System Operation: Not
tested - Not tested. Gas
not turned on at time of inspection. Ameren Gas company representative
arrived during inspection to turn on gas and was unable to light pilot
on furnace. Recommend HVAC service person examine units and repair as
needed, Furnace nearing the end of it's design life |
| 16. |
|
Manufacturer: Williamson |
| 17. |
|
Model Number: T117-12-1 Serial
Number: AS203879 |
| 18. |
|
Type: Forced air. Capacity: N/A |
| 19. |
|
Area Served: 2nd floor
only Approximate Age: 20
-30 years |
| 20. |
|
Fuel Type: Natural gas |
| 21. |
Acceptable |
Heat Exchanger: 1 Burner |
| 22. |
|
Unable to Inspect: N/A |
| 23. |
Acceptable |
Blower Fan/Filter: Belt
drive with disposable filter |
| 24. |
Acceptable |
Distribution: Insulflex
duct |
| 25. |
Acceptable |
Draft Control: Automatic |
| 26. |
Acceptable |
Flue Pipe: Metal |
| 27. |
Acceptable |
Controls: Disconnect;
normal operating and safety controls observed. |
| 28. |
Acceptable |
Thermostats: Individual |